GAUSS-52700 -- GAUSS-52799

GAUSS-52700: “Failed to update ETCD.”

SQLSTATE: None

Description: Failed to update the ETCD.

Solution: Solve the problem based on the replace logs.

GAUSS-52701: “All the CMAgents instances are abnormal. Cannot fix the cluster.”

SQLSTATE: None

Description: All the CM Agent instances are damaged and the cluster cannot be restored.

Solution: Use gs_replace to perform warm backup.

GAUSS-52702: “The cluster status is Normal. There is no instance to fix.”

SQLSTATE: None

Description: The cluster status is normal and no instance needs to be restored.

Solution: Do not perform the restore operation.

GAUSS-52703: “The number of normal ETCD must be greater than half.”

SQLSTATE: None

Description: More than half of the ETCDs in the cluster must be normal.

Solution: Check whether the cluster status is normal after the warm backup and whether the number of normal ETCDs in the cluster exceeds half of the whole ETCDs.

GAUSS-52704: “Failed to check the %s condition.”

SQLSTATE: None

Description: Failed to check the condition.

Solution: Check whether the corresponding process is normal.

GAUSS-52705: “Failed to obtain ETCD key.”

SQLSTATE: None

Description: Failed to obtain the ETCD key.

Solution: View the etcdctl logs and solve the problem.

GAUSS-52706: “Failed to clean ETCD and touch flag file on %s.”

SQLSTATE: None

Description: Failed to clear ETCD instances and create flag files on the nodes.

Solution: Check whether there are sufficient permissions on corresponding nodes.

GAUSS-52707: “Failed to install on %s.”

SQLSTATE: None

Description: Failed to install the warm backup node.

Solution: Solve the problem based on the replace logs.

GAUSS-52708: “Failed to configure on %s.”

SQLSTATE: None

Description: Failed to configure the warm backup node.

Solution: Solve the problem based on the replace logs.

GAUSS-52709: “Failed to check the cluster configuration differences:”

SQLSTATE: None

Description: Failed to check the cluster configuration difference.

Solution: When performing the warm backup or modifying the IP address, check whether the XML file and the current cluster configuration are different. If they are the same, skip the preceding operations. Modify the XML configuration information again.

GAUSS-52710: “Replacement failed.”

SQLSTATE: None

Description: Failed to replace the instance.

Solution: View the logs and find out detailed failure information.

GAUSS-52711: “Failed to set CMAgent start mode.”

SQLSTATE: None

Description: Failed to set the CM Agent startup mode.

Solution: View the etcdctl logs and solve the problem.

GAUSS-52712: “Failed to read step file with erro:[%s].”

SQLSTATE: None

Description:Internal system error.

Solution:Contact technical support.

GAUSS-52713: “Failed to repair cm_server, errorinfo:[%s].”

SQLSTATE: None

Description:Internal system error.

Solution:Contact technical support.

GAUSS-52714: “Failed to write step file, errorinfo:[%s].”

SQLSTATE: None

Description:Internal system error.

Solution:Contact technical support.

Feedback
编组 3备份
    openGauss 2024-05-06 00:44:54
    cancel